Concrete masonry has wide applications in modern industrial commercial educational and residential.
Concrete floor slab to masonry block detail.
Detail 1 3a brick veneer concrete block detail at slab edge for load bearing wall detail 1 4 brick veneer concrete block detail at slab edge detail 1 5 membrane air barrier detail at movement joint.
This compilation includes hundreds of details for brick block and stone masonry systems as well as details for ceramic tile marble terrazzo plaster rainscreen systems terra cotta aac and masonry restoration.
The top steel reinforcement is important.
140 mm blocks or a 90 mm and 190 mm block.
Although provided as a guide only common sense and job specific detailing can be added by qualified designers.
The cores on opposing slabs need to.
Shelf angle detail anchored brick veneer cmu backing shelf angle with bracket type standoffs 01 030 0721.
Concrete slabs can take many forms including prestressed precast and cast in place construction.
Alternative floor slab detail.
The details are developed by imi s technical team of architects and engineers and are reviewed by international masonry.
Figures 4 12 through 4 14 show variations where the slab is the primary location for insulation.
The slab is constructed on well compacted granular fill crushed stone or marl.
The cores are then filled with in situ concrete to form the tie detail.
Typically two cores per 1200mm wide slab are formed open so that a reinforcement bar can be inserted across the slabs.
4 2 slab on grade construction details.
This tek contains details for various types of concrete masonry foundation walls with accompanying text as appropriate.
Roof detail high wall low roof.
The mesh reinforcement in the slab is placed in the top with 1 covers.
Roof detail pitched roof to high wall 01 030 0751.
Steel bar joists typically use pocketed or ledger connections to concrete masonry walls.
Concrete floor slab 15 mpa concrete infill of cavity to ngl level damproof sheeting dpc 60 110 cavity 90 90.
For walls narrower than 190mm the slabs need tying together to allow for construction and manufacturing tolerances.
Details of concrete masonry 5 cavity walls 240 mm to 290 mm reference c computer.
The suspended reinforced concrete slab is tied into the external capping beam at floor level.
Proprietary systems that use concrete masonry units as a filler between the steel joists are also available.
In this section several typical slab on grade sections are illustrated and described.