As stated in 90 1 a of the national electrical code nec the purpose of the code is the practical safeguarding of people and property from hazards arising from the use of electricity.
Conduit clearance above floor nec.
This requirement first appeared in the 1987 nec.
A service panel requires a working clearance that s 30 in.
Procedures when constructing a raceway for conduit the number of bends is limited to three regardless of the degree of the bend.
If you are less thaan that a 1 16 steel plate may be installed to prevent puncture if not in conduit.
The only standard height for work areas i have ever heard of was 30 above a work area.
Here s a good rule of thumb.
In this installation no circuit breaker in its highest position is more than 6 feet 7 inches above the floor.
110 26 a 3 e as a general rule you must maintain a minimum headroom clearance of 6 ft from the floor or platform up to any overhead obstruction.
This workspace is mandatory and applies to service equipment switchboards panelboards and motor control centers.
There is no height requirement in nec article 358 12 uses not permitted so long as the run meets the other requirements.
The top of the disconnect switch is only 72 inches 6 feet above the floor.
Buried wiring runs that transition from underground to above ground must be protected in conduit from the required cover depth or 18 inches whichever is less to its termination point above ground or at least 8 feet above grade.
Conduit raceways use schedule 40 pvc conduit whether they are the primary or secondary conduit raceways.
Cables shall be installed in metal raceways or rigid nonmetallic conduit where passing through a floor or wall to a height of 2 1 m 7 ft above the floor unless adequate protection can be afforded by building construction such as detailed in 760 130 b 1 or unless an equivalent solid guard is provided.
Wide three feet deep and six feet eight inches high in the national electric code.
However from an owner s perspective.
Therefore this installation complies with 404 8 a.
The above referenced nec space requirements must be complied with in all situations.
Height of working space sec.
If you look in the nec article 300 4 sub section d cables and raceways parallel to framing members it says that you must maintain a 1 1 4 clearance form the nearest edge of the framing member or deck in your instance.
If you can t park a refrigerator in front of the panel you don t have enough working space.
2 passing through a floor or wall.
If a bend in the conduit is required it must be done at the shop in a controlled environment to ensure the.
However complying with nec rules and regulations will not necessarily provide an installation that is efficient convenient or adequate for good service or future expansion of electrical use.
Electrical equipment floor space.
There is also no height requirement for task lighting over a work area.