Consult your product specific o m manual before conducting maintenance on the unit.
Cooling tower preventive maintenance checklist.
Different environmental conditions may dictate more frequent servicing.
The cold water basin should be flushed and cleaned with the suction strainer screens in place.
Cooling tower inspection checklist and calendar general recommendations more frequent inspection and maintenance intervals may be desirable.
Preventive maintenance checklist preventive maintenance tasks on cooling towers should be conducted daily weekly semi annually or annually depending on the task.
See the updated article.
1 3 ensure cooling tower operation complies with nys doh legionella regulations.
Cooling tower preventative maintenance checklist.
Each day technicians should perform an overall visual inspection when they sequence coolers and ensure that water is flowing appropriately.
The program is designed to.
This content has been revised as per the new nyc cooling tower legislation.
Back to faqs definitions.
Cooling towers evaporative condensers and closed circuit cooling towers.
Keeping your cooling tower running.
Operation and maintenance instructions seasonal shut down checklist when the system is to be shut down for an extended period of time the following services should be performed.
The purpose is to define a preventive maintenance program and plan for cooling towers at the suny polytechnic quad c building utica new york.
Stick to a regular maintenance schedule to reduce the risk of legionella and prevent premature failure recommends dan glover technical services group manager for southland industries a national mechanical engineering construction and service firm.
Keeping your cooling tower in good shape requires more than just the annual inspection before startup.
08 31 2018 cooling tower preventative maintenance checklist.
Recommended service intervals are the minimum for typical installations.
The frequency of maintenance procedures varies depending on various factors like the condition or quality of the water circulating in it as well as the location and environment where the cooling tower operates.
Following the recent legionnaires disease outbreaks there is a great deal of concern and uncertainty about what is required for proper cooling tower maintenance.
The 14 maintenance checklist mentioned above will greatly help you determine possible problems on the cooling tower system fix.
The evaporative cooling unit cold water basin should be drained 2.